Rasci Calibration Service
Solution Partner in Calibration Technology www.rasciinstruments.com
Temperature Calibrator , Pressure Calibrator
□ All in one Rasci Calibration Services
□ Electro Thermal/Thermal/Mechanical
□ Laboratory and On Site Calibration
□ Furnace, Oven and Chamber /Cooker
□ National Standard Traceable Certificate
□ ETDC and ATI Trained Engineers
□ Calibration Mapping and Validation
□ Temperature, Pressure, Humidity
□ Micrometer, Vernier and Measuring Scale
□ Pressure Gauge and Thermometer etc…
□ Available Various models Instruments
□ Optional for NABL Accreditation
Rasci
calibration services have all range of process control
Instruments (Temperature, Humidity, pressure, voltage, current, flow
etc) mechanical measuring instruments
( vernier caliber, measuring
scale,
Micrometer, height gauge etc) , thermal calibration mapping & validation
At site . On site
calibration process control instruments , furnace, oven
Humidity and temperature
chamber , clean room etc… we
have high
Accuracy calibrators with traceable from national standard
laboratories.
We provide proper calculated calibration certificate suitable for
ISO 9000
And quality assurance. We maintain periodically calibration chart.
Rasci also undertaken service, AMC, consultant service and site calibration. Our technical supported with
ETDC trained engineers find out solution
on
Technical issues related to and instruments range or products at
anytime.
We provide
calibration instruments with national standards traceability certificate from
NABL labs. An ISO 9001 : 2008 Quality
Certified.
RASCI INSTRUMENTS
An
ISO 9001:2008 Certified Company
Plot No : 2&3, 4th
Street, Balaji Nagar, Mettukuppam
Thoraipakkam, Chennai-600
097,
Telefax : +91-44-24580776
Mobile : +91-9444060776,
Customer Care : +91-9841630776
□ All in one Temperature Calibrator
□ High Accuracy with Power Saving
□ Suitable for Temperature Sensor Calibration
□ Man/Auto with On/off/PID/Program Control
□ Double
High Quality LED Display
□ Adopt ITS -90 Thermometric Scale
□ Cold junction Compensation in T/Cs
□ Communication RS 485 with Software
□ Temperature Logger or Recorder
□ Heavy Duty Branded Tyristor
□ Available Various models /Function
□ 9
Profile with 16/32/64 Segment Program
Low Cost High Quality
Rasci
calibration bath outer fabrication of
Mild steel with powder coated The RTCH are insulated with high
alumina insulation brick work Followed by and ceramic
fiber mat to reduce the radiation heat
loss to Minimum This is suitable for thermocouple and Rtd
sensors calibration
Method of master
Comparison. High accuracy temperature controller With Tyristor
based control circuit. The RTCH
heated by kanthal A1 Heating coils. Insulation with
high q uality superior quality ceramic
fiber Blanket. The temperature inside is maintained any desired level with in the operating range by a
digital automatic temperature controller.
Rasci also offered Mp based high accuracy customized controller
With Strip chart Recorder ,Temperature data logger
for PC interfacing , Memory storage
1000 data per channel Direct printer port and Suitable
software package.
The calibration bath
is compact size, priced very competitive. The unit can be drawn from the front
for Easy servicing. An ISO 9001 : 2008 Quality Certified
RASCI INSTRUMENTS
An ISO 9001:2008 Certified Company
Plot No : 2&3, 4th Street, Balaji Nagar, Mettukuppam
Thoraipakkam, Chennai-600 097, Telefax : +91-44-24580776
Mobile : +91-9444060776, Customer Care : +91-9841630776
Technical Specification
RMFC
|
11
|
14
|
15
|
25
|
Process
|
Temperature
|
Voltage/Current
|
Multi -Process
|
|
Function
|
Measure
|
Measure
|
Measure
|
Measure
|
Accuracy
|
-
|
±0.02
%
|
±0.02
%
|
±0.02
%
|
DC Voltage
|
-
|
- 5.000 – 550.00mV
|
-20.00mV -55.000V
|
-5.000mV
– 55.00V
|
DC Current
|
-
|
-
|
-4.000
– 55.000mA
|
-5.000 – 50.000mA
|
Ohms
|
-
|
0.00 Ω
- 5.500kΩ
|
-
|
0.00 Ω
- 5.5000kΩ
|
Frequency
|
-
|
1.00Hz
– 110 KHz
|
3Hz –
50.000 KHz
|
2Hz –
11.0 KHz
|
Thermocouple
|
-
|
R,S,B,E,K,J,T,N,L,U
|
-
|
R,S,K,E,J,T,N,B
|
Thermo resistance
|
-
|
Pt
100,Pt1000,Cu50
|
-
|
Pt100,Pt1000,Cu50
|
Switch
|
-
|
-
|
Close/Open
|
Close/Open
|
Pressure
|
-
|
-
|
Pressure
module
|
-
|
Function
|
Source
|
Source
|
Source
|
Source
|
Accuracy
|
±0.02
%
|
±0.02
%
|
±0.02
%
|
±0.02
%
|
DC Voltage
|
-10.000mV -11.000V
|
-10.000mV -1100.0V
|
-100.00mV -11.000V
|
-5.000mV
– 55.00V
|
DC Current
|
0.000mA
– 22.000mA
|
-
|
0.000mA
– 22.000mA
|
-5.000 – 50.000mA
|
Ohms
|
0.00 Ω
- 40.000kΩ
|
0.00 Ω
- 4.0000kΩ
|
-
|
0.00 Ω
- 40.000kΩ
|
Frequency
|
1.00Hz
– 110 KHz
|
-
|
1.00Hz
– 11.0 KHz
|
1.00Hz
– 110 KHz
|
Thermocouple
|
R,S,B,E,K,J,T,N,L,U
|
R,S,B,E,K,J,T,N,L,U
|
-
|
R,S,K,E,J,T,N,B
|
Thermo resistance
|
Pt
100,Pt1000,Cu50
|
Pt
100,Pt1000,Cu50
|
-
|
Pt100,Pt1000,Cu50
|
Switch
|
1.00Hz
– 110 KHz
|
-
|
-
|
0.1Hz – 1 KHz
|
Pulse
|
1 –
100000 Cycles
|
-
|
1 –
100000 Cycles
|
10
-100000 cycles
|
Loop
|
-
|
-
|
24 VDC
|
24 VDC
|
Pressure
|
-
|
-
|
-
|
2.49Kpa
-70Mpa
|
Size
|
205X95X42
mm
|
205X95X42
mm
|
205X95X42
mm
|
205X95X42
mm
|
General Specification
Power
|
4 X 1.5 V AAA
alkalescence battery / electricize battery
|
Working environment
|
0 - 50 º C , ≤ 80 % Rh ; 70 % Rh < 40 -50 º C
|
Shake and concussion
|
Randomicity 2 g, 5-500 Hz testing under I meter
|
Proof cycle
|
1 year
|
Warm – up time
|
Boot-strap warm-up time in 10 minute or other
|
Application
□
Testing and calibration laboratories
□
Automobile and power industries
□
Pharmaceutical and Chemical industries
Contact
us
Authorised Dealer
RASCI INSTRUMENTS
An
ISO 9001:2008 Certified Company
Plot No : 2&3, 4th
Street, Balaji Nagar, Mettukuppam
Thoraipakkam, Chennai-600
097,
Telefax : +91-44-24580776
Mobile : +91-9444060776,
Customer Care : +91-9841630776
Email:rascinsts@yahoo.co.in,solution@rasciinstruments.com